Applied-motion SWM24IP-3EE Manuale Utente Pagina 30

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 36
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 29
CONTROLLER: -S, -Q, -IP Models
IN1 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CW limit, general purpose input.
IN2 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CCW limit, general purpose input.
IN3 Optically isolated, 5-24 V, 8-12 mA.
Function: home sensor, general purpose input.
OUT Optically isolated, 30V, 40mA MAX. open emitter/collector.
Function: fault, motion, alarm, tach or general purpose
30
SWM24 Hardware Manual
920-0068B
10/31/2013
Vedere la pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 36

Commenti su questo manuale

Nessun commento